what use of conductivity/tds meter in wastewater treatment plant?

by Ettie Ortiz Published 2 years ago Updated 2 years ago

Conductivity measurements can be used to monitor the processes in wastewater treatment that causes changes in conductivity. The processes that in many treatment plants cause changes in conductivity are mainly biological nitrogen removal.

A TDS meter, therefore, measures the conductivity of a water sample and uses this figure to determine water's TDS level. This level is measured in parts per million (ppm) or milligrams per liter (mg/L).Jul 12, 2021

Full Answer

What is the purpose of measuring conductivity in wastewater treatment?

 · Conductivity meters are also used to measure the TDS build-up inside boilers and to automatically open and close a control valve to blow down the boiler contents and lower the TDS. The probe senses the contamination increasing as water is boiled away into steam.

What causes conductivity to change in wastewater treatment plants?

Conductivity in Wastewater. The total amount of dissolved salts has a big impact on the wastewater and its treatment. The higher the salinity the less oxygen gets dissolved which may influence the bacteria at the biological treatment step. Other effects of high salinity might be corrosion of metals or concrete, or scale formation leading to difficulties in the operation of the …

What is the difference between TDS meters and conductivity?

 · TDS meters measure the electrical conductivity of water. Pure water is a poor conductor, but total dissolved solids carry a distinct electrical charge that correlates directly to TDS levels. The greater the charge — the higher the level of dissolved solids. It’s the quickest way to get a feel of what in your water.

Why test tap water with a TDS meter?

Conductivity measurements can be used to monitor the processes in wastewater treatment that causes changes in conductivity. The processes that in many treatment plants cause changes …

What is the purpose of conductivity meter?

Conductivity meter allows us to measure the level of conductivity in solutions. Conductivity is an ability of materials (solutions, metals or gases) to pass an electric current.

What is TDS conductivity meter?

Pocket Conductivity / TDS Meter This multi-functional pen type water quality meter measures conductivity and total dissolved solids to determine water quality.

Why is conductivity important in wastewater?

The reason that the conductivity of water is important is because it can tell you how much dissolved substances, chemicals, and minerals are present in the water. Higher amounts of these impurities will lead to a higher conductivity.

What does conductivity measure in water treatment?

What is conductivity? Conductivity is a measure of the ability of water to pass an electrical current. Because dissolved salts and other inorganic chemicals conduct electrical current, conductivity increases as salinity increases.

What's the difference between TDS and conductivity?

Total Dissolved Solids (TDS) and Electrical Conductivity (EC) are two separate parameters. TDS, in layman's terms, is the combined total of solids dissolved in water. EC is the ability of something to conduct electricity (in this case, water's ability to conduct electricity).

What is EC water test?

An EC meter makes testing and monitoring the electrical conductivity of water simple. EC water conductivity test equipment can be used in the field to take direct measurements of water. The probe that is inserted into the water sample applies a voltage between electrodes.

How is TDS and conductivity related?

Conductivity (EC) and total dissolved solids (TDS) are water quality parameters, which are used to describe salinity level. These two parameters are correlated and usually expressed by a simple equation: TDS = k EC (in 25 °C).

What is conductivity of wastewater?

The total amount of dissolved salts has a big impact on the wastewater and its treatment. The higher the salinity the less oxygen gets dissolved which may influence the bacteria at the biological treatment step.

How can conductivity be reduced in wastewater?

Studies have shown that the conductivity of wastewater can be reduced by biological nutrient removal which can be explained by the algal-bacteria symbiosis.

How conductivity affects water quality?

Electrical conductivity measures the ability of water to conduct an electrical current. The higher the concentration of dissolved charged chemicals (also known as salts) in the water, the greater the electrical current that can be conducted.

What is conductivity test?

Conductivity meters measure the ion capacity in aqueous solution to carry electrical current. As the ranges in aqueous solutions are usually small, the basic untis of measurements are milliSiemens/cm (mS/cm) and microSiemens/cm (μS/cm).

What is unit of conductivity?

The unit of electrical conductivity is, by definition, the reciprocal of electrical resistivity, S/m (siemens per meter) in SI units.

What is a TDS meter?

TDS meters are a handy new way to evaluate water quality. Inexpensive, reliable and straightforward to use, these must-have digital devices measure contaminant levels in seconds. But while TDS meters offer a glimpse of what may be lurking in your cup, they don’t tell the whole story. Let’s take a closer look at their capabilities, limitations, and how they fit into your comprehensive water safety plan.

Why is TDS important in fish tanks?

Similarly, checking levels in fish tanks improves the habitat and keeps testing costs under control.

Can a water main break cause a sharp rise in dissolved solids?

A water main break, for example, may cause a sharp rise in dissolved solids that can carry potentially dangerous contaminants with them. If you can only afford a water test or a TDS meter, choose the test. But for less than $20, a meter offers enough peace of mind to be a worthwhile investment. If you already have a TDS meter, you’re ...

Can shallow wells be contaminated?

Finally, it’s not unusual for shallow wells to become contaminated with solids in areas pro ne to flooding . A quick check with a TDS meter can tell you if floodwaters have infiltrated your well and further testing is required. Meanwhile, you can keep your family safe by switching to bottled.

Can aquarium filters remove TDS?

Aquarium filters only remove Total Suspended Solids (TSS). Once tested, aquarists can test tap water with a meter before adding it to the tank, blending it with purified water to achieve an ideal TDS balance while saving more expensive test strips only to troubleshoot specific substances. It’s a money saver.

Is a TDS meter good for water quality?

TDS meters aren’t a substitute for water testing, but they can play an important role in monitoring your home water quality. Since most dissolved solids are likely to be minerals, gardeners benefit by knowing what they’re watering plants with. Higher TDS levels are beneficial for most flowers and vegetables. Fans of alkaline water and its many ...

Is high TDS bad for you?

High TDS levels are not necessarily unhealthy, but they can reflect significant water quality issues that would benefit from filtration. Hard water, for example — water with high levels of calcium and magnesium — has a bitter taste and can be unpalatable to drink.

What is the relationship between activated sludge microbiota and wastewater treatment plant?

The relationship between a quality of activated sludge microbiota and wastewater treatment plant (WWTP) operational stability has been defined in the past few decades. However, this dependence is not so clear in the case of industrial wastewater treatment. In this article, a very specific example of industrial textile wastewater treatment plant (ITWTP) is analyzed. Textile effluents are well known as highly contaminated wastewater containing many biodegradable compounds. Microscopic analysis included flocs morphology examination, attempts to evaluate the Sludge Biotic Index (SBI), and identification of dominant filamentous microorganisms. Routine operational control of ITWTP covered pH, temperature, redox potential, dissolved oxygen and COD measurements. The average ecosystem existing in the described ITWTP differed significantly compared to municipal WWTPs. The flocs were smaller and irregular. Filamentous bacteria did not cause foaming although filaments index reached 4. Nostocoida limicola I dominated with significant amounts of type 0041 and type 021N. The evaluation of SBI was impossible as the most of protozoan was in the form of cysts. The overall microbiota diversity correlated with COD removal in activated sludge unit of ITWTP.

What is the ionic conductivity of phosphorus removing sludge?

The ionic conductivity of an enhanced biological phosphorus removing (EBPR) sludge shows a clear behavior during the non-aerated phase. It decreases during denitrification and increases under anaerobic conditions proportionally to the phosphate concentration. The absolute value of this increase related to the release of phosphorus was determined between 1.66 × 10−4 to 1.99 × 10−4 S m2 g−1P (at 293 K and an ionic strength of about 650 × 10−4 S m−1). Theoretical calculations are in good agreement with these results. Potassium, magnesium, calcium and phosphate show a positive, whereas acetate and pH show a negative correlation to the ionic conductivity. This method is an easy and inexpensive in-line method providing more information about phosphorus release. Under some circumstances (low salinity, sequencing batch reactor) it may be used to estimate the anaerobic increase of phosphorus concentration.

How does calcium affect phosphorus removal?

The role of calcium (Ca) in enhanced biological phosphorus removal and its possible implications on the metabolic pathway have been studied. The experience has been carried out in an SBR under anaerobic-aerobic conditions for biological phosphorus removal during 8 months. The variations of influent Ca concentration showed a clear influence on the EBPR process, detecting significant changes in Y (PO4). These Y (PO4) variations were not due to influent P/COD ratio, pH, denitrification and calcium phosphate formation. The Y (PO4) has been found to be highly dependent on the Ca concentration, increasing as Ca concentration decreases. The results suggest that high Ca concentrations produce "inert" granules of polyphosphate with Ca as a counterion that are not involved in P release and uptake. Furthermore, microbiological observations confirmed that appreciable changes in PAO and GAO populations were not observed. This behaviour could suggest a change in the bacterial metabolic pathway, with prevailing polyphosphate-accumulating metabolism (PAM) at low influent Ca concentration and glycogen-accumulating metabolism (GAM) at high concentration.

How does ionic conductivity affect phosphorus?

Conductivity shows a strong correlation with phosphorus in both anaerobic and aerobic stages, increasing or decreasing when phosphorus is released or taken up , respectively. Since the end of these processes can be detected by examining the conductivity profile in a cycle, useful information on the EBPR performance and stability is available. This information can be used for adjusting the length of the anaerobic and aerobic stages. Therefore, online process control based on inexpensive and easy to maintain sensors could be applied. Laboratory scale experiments were conducted to study the most significant ions concentration behaviour in a sequencing batch reactor (SBR) operated for EBPR as well as the conductivity and pH profiles. Statistical analysis of the experimental data also showed a strong correlation between metal cations and phosphorus concentrations (0.28molKmolP−1 and 0.36molMgmolP−1). The model used in the simulation stage (BNRM1) takes account of all the ions that play an important role in the EBPR process as well as the pH value. Model predictions accurately reproduced the experimental data.

Why are dairy plants considered wet?

Dairy plants are categorized under wet industry because large volume of water is used for its product processing stages. Current statistics shows India is ranked one in the global milk producers. The waste which is generated from the dairy plant is there for a hot topic for engineering discussions. The dairy industry, like most other agro-industries, generates wastewater characterized by high chemical oxygen demand (COD) and Biological oxygen demand (BOD) due to their high organic content. The dairy-industry wastewater is primarily generated from the cleaning and washing operations in milk processing plants, milk transportation vehicles, fault product discharge etc. Even though the biological treatment processes offer a cost effective method to remove organic compounds and nitrogen from the wastewater, the fat content in dairy effluent after aerobic treatment system is still a problem to be managed. Oil containing sludge produced after aerobic treatment is discarded from dairy treatment plants for land filling, which cause severe Environmental imbalances. More over in most cases product ideas from the waste dairy effluent fat is beyond the scopes of the current treatment processes. The aim of this work is to design a process mediated by Cyclone baffled Reactor and Potash Alum, which have the capability to enhance current dairy treatment process by separating fat content of dairy effluent at the initial stages itself prior to biological treatment steps. Results shows COD reduction of 70.73% and BOD reduction of 70.58% was achieved in CBR with a retention period of 20 minutes. Reduction in effluent treatment retention time and effective fat separation from the dairy effluent, thereby reducing the BOD and COD loads are the final outcome of this work.

What is the purpose of phosphonates in membranes?

The use of phosphonates as antiscalants in membrane processes is common. Before they are discharged into the receiving water, they should be removed from the membrane concentrate to protect the aquatic environment. This study conducted fixed-bed column experiments on the adsorption of diethylenetriaminepenta (methylene phosphonic acid) (DTPMP) and ortho-phosphate on granular ferric (hydr)oxide (GFH). The objective was to investigate the adsorption and desorption performance using real membrane concentrate, while testing both the usability of the GFH and that of the regeneration solutions over multiple cycles. Whereas a synthetic solution with DTPMP allowed almost complete regeneration, the adsorption performance with real membrane concentrate at the original pH ≅ 8 decreased significantly. This could be attributed to the precipitation of calcium compounds which disturbed the adsorption/desorption process. With the introduction of a novel acidic regeneration step to remove the precipitates, an adsorption performance of 95% over 20 cycles was achieved. The hydrochloric acid (HCl) can be reused when its pH is kept constant by a pH control. The sodium hydroxide solution (NaOH) for alkaline regeneration can be reused several times. However, the desorption performance decreased significantly when its electrical conductivity dropped below 90 mS/cm. Replacing the NaOH regularly can significantly improve the desorption performance.

Is wastewater good for reuse?

Increased global demand for freshwater far exceeds the quantity available for human sustenance. Wastewater recycling processes are necessary and capable of producing large volumes of water for reuse. In this study, raw kitchen wastewater was analyzed for physicochemical and microbiological characteristics before and after biological treatment and sand-bed filtration. The results revealed a reduction in the mean values of the following parameters: turbidity (from 6.9 to 6 NTU, a 13.04% reduction), conductivity (365 to 311 µS/cm, a 14.79% reduction), total dissolved solids (141 to 121 mg/L, a 14.18% reduction), total suspended solids (5 to 2 mg/L, a 60% reduction), biochemical oxygen demand (5.5 to 1.82 mg/L, a 66.9% reduction), chemical oxygen demand (36 to 32 mg/L, an 11.11% reduction), and total bacterial count (286 x 10-4 to 16 x 10-4 CFU, a 94.41% reduction). The kitchen wastewater was suitable for non-potable reuse. Biological treatment and sand-bed filtration rendered the kitchen wastewater useful for secondary applications such as irrigation.

How does TDS affect wastewater treatment plants?

TDS can dramatically affect plant operation or compromise a facility’s ability to meet NPDES permit limits. TDS ions are not regulated pollutants, but the concentration of TDS in plant influent may have a significant effect on plant processes and the ability to meet permit limits. New or expanding industry to an area facilitates economic development. Most utilities do not desire to turn away high TDS -discharging industries from relocating to an area; however, the impact to a wastewater treatment facility’s operation and the increased likelihood of NPDES permit violations is a significant concern.

Who wrote the WET test?

Authors: Mary Sadler, PE, Robbie Graham, Clarke Wallcraft, Janice Carroll, PE. The WET test was designed in two parts. The first part consisted of a single salt spiked test to see if there was an individual salt that may be more problematic that the others.

Is TDS a regulated ion?

TDS ions are not regulated pollutants, but the concentration of TDS in plant influent may have a significant effect on plant processes and the ability to meet permit limits. New or expanding industry to an area facilitates economic development.

What is Conductivity in Water?

Electrical conductivity, or specific conductance, refers to how well a medium conducts electricity. We know that water conducts electricity, which is why we don’t go swimming during a thunderstorm or use a hair dryer in the bathtub. However, water is not a good conductor of electricity on its own.

How to Measure Salinity and TDS

The conductivity measurement units you use will depend on your location and the conventions of your application. Each industry has a preferred unit of conductance. Note that TDS (expressed in mg/L or ppm) actually refers to the number of ions present, not the electrical conductivity.

How to Convert Conductivity to Concentration

The conversion between conductivity and TDS or salinity depends on the chemical composition of the sample. TDS measurements are typically used for environmental monitoring, where most dissolved solids are ionic. Different ions produce different values of electrical conductivity.

Conductivity in Water Treatment

Different applications require different levels of water purity. As an example, the electrical conductivity of drinking water will usually be less than 1 mS/cm. Meanwhile, the semiconductor and pharmaceutical industries require extremely pure water, with an even lower electrical conductivity value than drinking water.

What is the standard solution for conductivity?

Use a conductivity standard solution (usually potassium chloride or sodium chloride) to calibrate the meter for the range that you will be measuring. The manufacturer's directions should describe the preparation procedures for the standard solutio n.

How much does a conductivity meter cost?

Suitable conductivity meters cost about $350. Meters in this price range should also measure temperature and automatically compensate for temperature in the conductivity reading. Conductivity can be measured in the field or the lab. In most cases, it is probably better if the samples are collected in the field and taken to a lab for testing. In this way several teams of volunteers can collect samples simultaneously. If it is important to test in the field, meters designed for field use can be obtained for around the same cost mentioned above.

How to clean a probe?

Rinse the probe with distilled or deionized water.

How to measure conductivity?

Conductivity is measured with a probe and a meter. Voltage is applied between two electrodes in a probe immersed in the sample water. The drop in voltage caused by the resistance of the water is used to calculate the conductivity per centimeter. The meter converts the probe measurement to micromhos per centimeter and displays the result for the user. NOTE: Some conductivity meters can also be used to test for total dissolved solids and salinity. The total dissolved solids concentration in milligrams per liter (mg/L) can also be calculated by multiplying the conductivity result by a factor between 0.55 and 0.9, which is empirically determined (see Standard Methods #2510, APHA 1992).

Why is conductivity important?

Conductivity is useful as a general measure of stream water quality. Each stream tends to have a relatively constant range of conductivity that, once established, can be used as a baseline for comparison with regular conductivity measurements.

What is the unit of measurement of conductivity?

The basic unit of measurement of conductivity is the mho or siemens. Conductivity is measured in micromhos per centimeter (µmhos/cm) or microsiemens per centimeter (µs/cm). Distilled water has a conductivity in the range of 0.5 to 3 µmhos/cm. The conductivity of rivers in the United States generally ranges from 50 to 1500 µmhos/cm. Studies of inland fresh waters indicate that streams supporting good mixed fisheries have a range between 150 and 500 µhos/cm. Conductivity outside this range could indicate that the water is not suitable for certain species of fish or macroinvertebrates. Industrial waters can range as high as 10,000 µmhos/cm.

How does ground water affect conductivity?

Discharges to streams can change the conductivity depending on their make-up. A failing sewage system would raise the conductivity because of the presence of chloride, phosphate, and nitrate; an oil spill would lower the conductivity.