what are normal bod values for a wastewater treatment plant mg/l

by Prof. Hardy Schneider IV Published 2 years ago Updated 2 years ago
image

Most package sewage treatment plants or package wastewater treatment plants such as the BMS Blivet are designed to produce 25 mg/l of BOD at a minimum but much stringent more stringent BOD levels down to 5 mg/l can be produced if specified. Next up will be Suspended Solids (SS)

The Significance of BOD in Wastewater Treatment
Typical maximum values range from 10 mg/L for direct environmental disposal and 300 mg/L for disposal to sewer systems.
Oct 30, 2018

Full Answer

What are the BOD values for wastewater?

Oct 30, 2018 · Regulations concerning permissible BOD levels for wastewater disposal in industries and municipalities vary from state to state. BOD is listed as a conventional pollutant under the U.S. Clean Water Act. Typical maximum values range from 10 mg/L for direct environmental disposal and 300 mg/L for disposal to sewer systems.

What is the maximum acceptable level of BOD in the environment?

5, TSS, and FOG for wastewater influent. The most commonly used range is 100-300 mg/L BOD 5and 100-350 mg/L TSS (NSF Standard No. 40). FOG ranges typically are identified as 50-150 mg/L with 150 mg/L being identified as “strong”. Effluent:Conventional household septic tank effluent was identified by one researcher as 90-384 mg/L BOD

What is biochemical oxygen demand (BOD) in wastewater?

May 23, 2018 · Most package sewage treatment plants or package wastewater treatment plants such as the BMS Blivet are designed to produce 25 mg/l of BOD at a minimum but much stringent more stringent BOD levels down to 5 mg/l can be produced if specified. Next …

What is BOD test in water treatment?

monthly average of less than 30 mg/l BOD (biochemical oxygen demand) and less than 30 mg/l suspended solids. Source: http://www.fao.org/docrep/ T0551E/t0551e05.htm#3.2.4%20tertiary%20andor%20advanced%20treatment

image

What is a good BOD level mg L?

BOD values are usually reported in either ppm values or in mg/L values. Unpolluted rivers typically have a BOD below 1 mg/L. Moderately polluted rivers vary between 2 to 8 mg/L. Untreated sewage averages between 200 and 600 mg/L while efficiently treated municipal sewage would be 20 mg/L or less.

What is the average BOD of wastewater?

Is My Wastewater "High-Strength"?Table 1. Typical concentrations of organics in untreated domestic wastewater.BOD (biochemical oxygen demand)mg/L190COD (chemical oxygen demand)mg/L430TOC (total organic carbon)mg/L140O&G (oil and grease)mg/L903 more rows

What is acceptable level for BOD in water?

Drinking water should have after 5 days a BOD of well below 1 mg/l. Acceptable wastewater from a sewage treatment plant should have a BOD of around 20 mg/l.

What are typical BOD values?

BOD values range widely; generally, pristine waters have a value below 1 mg l−1, moderately polluted waters 2–8 mg l−1, and treated municipal sewage 20 mg l−1. Standards for the discharge of effluent from WWTPs have the range 20–30 mg l−1 and require a minimum flow in receiving waters to ensure sufficient dilution.

How is BOD value calculated?

Biological Oxygen Demand (BOD): Therefore it is used to measure the amount of certain type of organic water pollution BOD is calculated by keeping a sample of water containing a known amount of oxygen for five days at 20 °C. The oxygen content is measured again and BOD is calculated.

How is BOD percentage calculated?

So, coming into the plant is 245 mg per liter of BOD and leaving there's 22 mg per liter. We have a formula that says efficiency or removal efficiency equals what's coming in minus what's coming out then you divide that by what's coming in and then we multiply by a 100 to convert the decimal to a percent.Jun 22, 2018

What is the minimum value of BOD in polluted water?

Clean water has BOD value less than 5 ppm. Polluted water has BOD value higher than 10 ppm.

What is a BOD reading?

Biochemical oxygen demand, or BOD, is a chemical procedure for determining the amount of dissolved oxygen needed by aerobic biological organisms in a body of water to break down organic material present in a given water sample at certain temperature over a specific time period.

What is BOD5 in wastewater?

Typically, municipal wastewater treatment plants will use BOD5 as a measure of the organic concentration into, and through, the wastewater plant. Industrial wastewater systems will more often use COD to measure the organic concentration moving through the treatment plant. In my experience, I see TOC being used much less often (rarely) ...

What is the BOD5 test?

The BOD5 test measures the oxygen consumed by microorganisms as they oxidize (consume or eat) the soluble organic matter in the wastewater. But the BOD5 test is a somewhat unreliable means of determining the amount of organic matter present in water. The test measures only the approximate amount of oxygen that will be required ...

How long does it take to test for organics in wastewater?

The often highly variable chemical composition and strength of industrial wastewater requires a much more rapid method for measuring the organic concentration, hence the use of the two hour COD test or, in some plants, the 30 minute TOC analysis.

What is the purpose of a wastewater test?

The test measures only the approximate amount of oxygen that will be required (absorbed or consumed) by a wastewater when it is exposed to air or oxygen for an extended period of time. Toxic substances in the wastewater inhibit or even prevent bacterial growth and, therefore, oxidation of the organic matter.

Sewage Parameters 1: BOD

Before discussing package sewage treatment it is best to explain the parameters used to define sewage both when it comes into a treatment plant (influent) and when it leaves a sewage treatment plant (effluent) One of the main parameters to consider is BOD or BOD5 which means Biochemical Oxygen Demand (the ’5′ refers to the sewage being tested for BOD over 5 days, which is standard when testing BOD levels).

A bit about the company

Butler Manufacturing Services is a family owned specialist manufacturer of package (all in one) products for sewage treatment and surface water treatment established in 1986 with exports to 38+ countries worldwide including the world leading Blivet package sewage treatment plant, a ‘one stop shop’ for all surface water products from design to installation including attenuation , interceptors , holding tanks (incl.

Most recent answer

Generally, BOD and COD values of wastewater are high when you compare it with normal water. It is because of the complex and some recalcitrant materials present in it. Efficient water treatment can reduce these values and can bring it back to the standard values. These values are different for different areas or cities.