Three common BOD reduction methods for wastewater treatment are:
- Wastewater clarification
- Wastewater separation (Coagulation & Flocculation)
- Anaerobic microbial decomposition
What is the 5-day BOD of the wastewater?
Oct 30, 2018 · Three common BOD reduction methods for wastewater treatment are: Wastewater clarification Wastewater separation (Coagulation & …
What are the biggest problems in wastewater treatment?
Apr 29, 2019 · The importance of removing solids and BOD in wastewater is just as important to a small office park as it is to an entire city. Wastewater treatment utilizes several delicate chemical processes to achieve an acceptable quality of water, which is analogous to an acceptable quality of life. Wastewater contains many elements which break down into ...
What is STP and BOD in sewage treatment?
Sep 01, 2017 · Generally speaking, domestic wastewater has a BOD and TSS of about 150 mg/L. Food processing plants and breweries can have wastewater with a BOD of about 10,000 mg/L and a TSS of 5,000 mg/L. To remove BOD, a wastewater treatment plant has to aerate the water, which requires a lot of horsepower, aka electricity.
What is the goal of wastewater treatment?
They pass through any filter and keep the BOD & COD high. Using Physico-chemical treatment of wastewater, in which you try to separate colloidal particles, is achieved through the addition...

How do you reduce BOD levels in wastewater?
These are the best practices for reducing BOD and TSS that facility managers should know:Focus on removing TSS from wastewater first. ... Get a properly sized EQ tank. ... Control the pH of the waste stream. ... Install a modern plate pack DAF made of stainless steel or plastic. ... Use a regenerative turbine air dissolution pump.More items...•Aug 16, 2018
What decreases biological oxygen demand?
The rate of oxygen consumption in a stream is affected by a number of variables: temperature, pH, the presence of certain kinds of microorganisms, and the type of organic and inorganic material in the water. BOD directly affects the amount of dissolved oxygen in rivers and streams.
What are the various methods for the BOD removal from wastewater?
The presented biological wastewater treatment processes include: (1) bioremediation of wastewater that includes aerobic treatment (oxidation ponds, aeration lagoons, aerobic bioreactors, activated sludge, percolating or trickling filters, biological filters, rotating biological contactors, biological removal of ...
How do you control chemical oxygen demand?
There are various proven methods for COD reduction in wastewater management. Two of the most common techniques for COD wastewater removal are: Wastewater separation (coagulation and flocculation) COD removal by microbial action.Nov 1, 2018
What causes BOD to decrease?
The bacteria metabolize the carbonaceous material or BOD in the wastewater as this food source, metabolizing it to carbon dioxide. This in turn reduces the BOD of the sewage, which is desirable.
How can we reduce BOD and COD in industrial wastewater?
You can reduce COD and BOD by adding hydrogen peroxide to the wastewater solution. The hydrogen peroxide will chemically attack the organics in the wastewater, degrading them and reducing the measured COD and BOD.
Does chlorine reduce BOD?
BOD reduction: Chlorine accomplishes BOD reduction by oxidation of organic compounds present in wastewaters. 4. Oxidation of metal ions: Metal ions which are in reduced state are oxidized by chlorine (e.g., ferrous to ferric ion and manganous to manganic ions).
What is activated sludge treatment and how does it does it reduce BOD in wastewater?
Successful BOD removal in an activated sludge process depends on studying and controlling some basics such as wastewater characteristics. Aeration is used to operate activated sludge process units and is perhaps the most frequently used process to remove biochemical oxygen demand (BOD) from wastewater.Jan 28, 2017
What is BOD removal efficiency?
We have a formula that says efficiency or removal efficiency equals what's coming in minus what's coming out then you divide that by what's coming in and then we multiply by a 100 to convert the decimal to a percent.Jun 22, 2018
What causes high BOD in wastewater?
BOD represents the amount of organic matter in a water supply; therefore, it increases when decaying plants, human or animal waste, and other organic compounds are added to water.Mar 12, 2020
How can we reduce ammonia nitrogen in wastewater?
The most widely used methods for removing ammonia from wastewater are air stripping [6,7], ion exchange [8,9], breakpoint chlorination [10], and biological nitrification-denitrification [11,12]. The traditional method of removing ammonia from municipal and industrial wastewaters is based on biological treatments.Oct 9, 2019
What is the ratio of BOD COD in the final effluent?
Typical values for the ratio of BOD/COD for untreated municipal wastewater are in the range from 0.3 to 0.8 (see in table 3)....Type of wastewaterBOD/CODBOD/TOCFinal effluent0.1 – 0.30.2 – 0.52 more rows
Why is BOD important?
BOD is a crucial factor in refining wastewater. The bacteria are important for breaking down substances, however too much BOD can cause unwanted amounts of bacteria. It can also drain receiving waters of oxygen which can kill fish and harm the environment.
Why is it important to remove solids from wastewater?
The importance of removing solids and BOD in wastewater is just as important to a small office park as it is to an entire city. Wastewater treatment utilizes several delicate chemical processes to achieve an acceptable quality of water, which is analogous to an acceptable quality of life. Wastewater contains many elements which break down ...
Is a septic system aerobic or anaerobic?
Many septic systems have both an aerobic and anaerobic process, while others focus on reducing the need of BOD altogether.
How to reduce BOD?
1. Focus on removing TSS from wastewater first. Reducing TSS will almost always reduce BOD too. First and foremost, use mechanical screens such as roto-strainers or bar screens to get large solids out. This will also protect your downstream Dissolved Air Flotation (DAF) equipment from damage or clogging. 2.
How often should I clean my DAF?
Modern high-rate DAFs require takedown and cleaning about every 2 weeks. And if you don’t clean it, you may be faced with clogging, solids separation problems, higher chemical feed rates, and higher TSS. Rather than clean it yourself, get a DAF that is self-draining and self-cleaning to save yourself a lot of work.
Why is TSS important?
You may already know that you have to control your TSS and BOD for several important reasons: TSS/BOD levels must adhere to state environmental regulations. High TSS levels can cause severe harm to wildlife and can make water unpalatable or even dangerous to human health.
Why use liquid chemistry?
Using liquid chemistry allows for full automation of the process at a low cost, eliminates wetting issues and fish eyes (undissolved clumps of polymer particles), and opens up a wide range of treatment chemistries. It is also much easier to switch products when a drum or tote runs out than to wait or discard a palate of dry bag polymer.
What is plate pack DAF?
A modern plate pack DAF will improve your TSS removal rates. It will also reduce the footprint size of the DAF and give you more leeway with flow and load tolerance.
What happens if you have an undersized DAF?
There’s only so much that chemical treatment can do. An undersized DAF or chemical feed equipment will result in poor TSS removal rates and chemical program failure. Companies are continually increasing production and flow rates, so you need to size your equipment with potential increases in mind.
What happens if the pH swings to either side of the window?
If the pH swings to either side of this window, polymer will be wasted or ineffective.
Most recent answer
i think you if you treat water before sand filtration, it will be efficient.
Similar questions and discussions
What are the method can use to reduces the COD & BOD level of the waste water ?
BOD Compliance
High concentrations of BOD in wastewater can lead to regulatory issues. By implementing a system to effectively reduce the BOD in the wastewater stream your company will have the ability to remain in compliance and reduce risk. This will save your company regulatory costs.
COD Compliance
Effluent with high concentrations of COD can lead to compliance issues. Our wastewater systems can significantly reduce the Chemical Oxygen Demand in your wastewater. We have saved our customers surcharges and headaches by reducing their COD wastewater.
Treatment Solutions
The two recommended aerobic treatment and reuse technologies include Membrane Bioreactor (MBR) Systems and Moving Bed Biofilm Reactor (MBBR) Systems.
Visit Our Blog
bioprocessH2O offers innovative wastewater and water reuse treatment technologies to serve a wide variety of industrial and decentralized markets.
What is BOD in wastewater?
Industries that discharge wastewater into municipal sanitary sewers or waterways are facing strict regulations on levels of biological or biochemical oxygen demand (BOD). Solid materials in wastewater can consist of organic and/or inorganic materials and organisms.
What is the purpose of biological oxygen demand?
Biological Oxygen Demand (BOD) is a chemical procedure for determining the amount of dissolved oxygen needed by aerobic biological organisms “bio-bugs” in a body of water to break down organic material present in a given water sample at a certain temperature over a specific time period.
How to reduce COD and BOD?
You can reduce COD and BOD by adding hydrogen peroxide to the wastewater solution. The hydrogen peroxide will chemically attack the organics in the wastewater, degrading them and reducing the measured COD and BOD. Hydrogen peroxide (H2O2) has been used to reduce the BOD and COD of industrial wastewaters for many years.
Why is water recycling important?
Water recycling allowing cost and energy savings to be made on the overall water usage as well as water treatment cost. an already existing water treatment system in order to reduce BOD and COD levels further. The use of ozone is a very cost efficient and environmentally friendly option for BOD and COD control and reduction.
What is hydrogen peroxide used for?
Hydrogen peroxide (H2O2) has been used to reduce the BOD and COD of industrial wastewaters for many years. While the cost of removing BOD and COD through chemical oxidation with hydrogen peroxide is typically greater than that through physical or biological means, there are nonetheless specific situations which justify the use of hydrogen peroxide. ...
Is ozone good for wastewater treatment?
Ozone is economically viable for Final step of waste water treatment before releasing it back into the environment or reuse ,otherwise economically viability depends on selection of technology and selection of technology depends on effluent conditions . Water treatment with ozone is an effective method to reduce BOD and COD levels in industrial ...
How to reduce COD in wastewater?
There are various proven methods for COD reduction in wastewater management. Two of the most common techniques for COD wastewater removal are: 1 Wastewater separation (coagulation and flocculation) 2 COD removal by microbial action.
Why is chemical oxygen demand important in wastewater treatment?
A key benefit of knowing the chemical oxygen demand in wastewater treatment is that it helps industrial and municipal clients determine the best method for treatment and the most effective structure for their wastewater treatment facility.
What is the best way to remove COD from sewage?
Another efficient technique for COD removal is to introduce bacteria or microorganisms that break down organic compounds present in the wastewater. Microbes in sewage treatment can be aerobic or anaerobic.
What is the chemical oxygen demand?
What Is Chemical Oxygen Demand? Chemical Oxygen Demand (COD) is the amount of oxygen required to oxidize all soluble and insoluble organic compounds present in a volume of water. COD value is usually expressed in milligrams per liter of water (mg/L).
What does high oxygen demand mean in water?
High chemical oxygen demand in water indicates greater levels of oxidizable organic matter and consequently, a lower amount of Dissolved Oxygen (DO). Critical DO depletion due to organic contamination can kill off aquatic life forms.
How long does it take to get a COD test?
The common technique uses COD vials for measurement and results are typically achieved within 2 – 3 hours.